Had a third party (that did not have any experience with product failure rates / history) conduct a DFMEA on a protection relay. The team identified 4 failure modes with RPN above acceptable levels. Turns out those 4 failure modes are on the units top 10 for service calls and repairs.
Even if not used as part of a Reliability Centred Enterprise Management Strategy DFMEAs provide great value.